Jan 14, Using the onboard software for a Nikon Total station. Using the onboard software for a Nikon Total station. Except for the none item, you cannot display the same item on more than one line of the same screen. You can also customize the displayed items in Stakeout. A hash symbol indicates that tilt correction is off. The input mode indicator in the status bar changes to show the current input mode.

When the cursor is in a height HT field, only numeric input mode is available. The PT field shows the default point name. Press any numeric key [0] through [9] to start measuring and recording points. A list of the numeric keys and their assigned feature codes appears on the right side of the screen. For example, when you press [6], the code assigned to 6 is selected, and the instrument starts a measurement.

If you have set the record mode to Confirm see Measurement settings, page 53 , the Record PT screen appears after each measurement. Do one of the following: — To record the point, press [ENT]. Then press the Edit softkey. You can use the List and Stack softkeys to enter the code.

Qcode observations To enter the Quick code observation routine, press the Qcode softkey. In this function, you can use the ten numeric keys to both select a feature code and shoot a point. To change the measurement mode for the Quick code observation, press the Sett softkey. Enter the height of the target, or press the Stack softkey to display the HT stack. The HT stack stores the last 20 HT values entered. Enter the ambient temperature and pressure. The ppm value is updated automatically.

Selecting the target set A target set specifies settings for the target type, the prism constant, and height of target. When you change the selected target set, all three settings are changed. You can use this function to quickly switch between two types of target, such as a reflector sheet and a prism. You can prepare up to five target sets. Then either press [3], or select Target and press [ENT].

A list of the five target sets appears. If you leave it blank, the current HT value is always applied to the measurement. If you have specified a value for HT, this value is also copied to the current HT. Then either press [4], or select Note and press [ENT]. This function can be used at any time on any observation screen.

Each note can be up to 50 characters. The note is stored as a CO record in the raw data. To display a list of previously used notes, press the Stack softkey. The stack stores the last 20 notes. Then press [ENT] to select the note. This function is available from any observation screen. Modify the default point name for the next record. Press [ENT] to confirm the new default point name.

The new point name is appears as the default PT name on the input screen. Bubble indicator To display the bubble indicator in an observation screen, press. When the leveling compensators are turned off, the text OFF appears on the screen. The DTM has vertical axis adjustment only. The current setting of leveling compensators is indicated by header characters :, , :, and after field labels such as HA, VA, SD, and HD in observation screens.

For more information, see Header characters, page Whenever you press a [USR] key, the function that is assigned to that key is activated directly. Hold down the [USR] key for one second to display the list of functions that can be assigned to the key. If you highlight a menu item and then press [ENT], a sub-menu appears. The first item on the sub-menu ends with the text [MENU]. If you select this item, the whole menu is assigned to the [USR] key. For more information, see [USR] key settings, page Use this screen to change the type of data that is assigned to [DAT].

Press [ESC] to return to the previous observation screen. For more information, see [DAT] key settings, page List Display 3. If the Page Up icon is displayed, there are more pages before the current page.

If the Page Down icon is displayed, there are more pages after the current page. To select an item from the list, move the cursor onto the item and press [ENT]. The default name for a new point is the last point name entered, with the last digit incremented. For example, if the last point name was A, the default name for the next point is A If the last character of the previous point name is alphabetic, the default point name is the last point name. When the cursor is in a PT point field, there are several ways to specify a point, or input coordinates.

Entering an existing point When you enter a known point name or number, the coordinates of that point are displayed briefly. A short beep sounds before the next screen appears or the next field is selected. The input coordinates are used in the calculation. They are not saved in the database. Recording an instant measurement You can also input a point by recording an instant measurement.

To do this, press the MSR softkey. An observation screen appears. To change the height of the target, press the HT softkey. To go to the point recording screen when you have finished the measurement, press [ENT].

Enter the point or code name. Press [ENT]. To display the stack, press the Stack softkey when the cursor is in the PT field. When you return to the point input screen, the selected point name is entered in the PT field, incremented by one. For example, if you selected the A point, A appears in the PT field. The stack shows the last 20 point names used, in chronological order from last used to first used.

Entering a point from the point list To display a list of existing points, press the List softkey when the cursor is in the PT field. When you return to the point input screen, the selected point name is entered in the PT field. You can add digits or alphabetic characters if required.

Entering a code For more information, see [COD] key, page You can use numeric or alphanumeric names up to 16 characters long to identify codes. Then use the keypad to enter the code. Entering a code from the stack The code stack is a list of recently used codes.

The stack may contain up to 20 codes. To display the stack, press the Stack softkey when the cursor is in the CD field. The selected code is copied to the CD field. When the instrument is rebooted, the code stack is cleared. Entering a code from the code list To display a list of existing codes, press the List softkey when the cursor is in the CD field.

For more information, see Editing an item in the point list or code list, page If you highlight a layer in the list and then press [ENT], the codes and layers in that layer are displayed. When you return to the input screen, the selected code is entered in the CD field. Items are shown in alphabetic order. You can also use the first character search to quickly find a code.

For more information, see Advanced feature: Searching for a code by using the first character, page Advanced feature: Searching for a code by using the first character To find a code quickly when the code list is displayed, use the first-character search.

For example, to see feature codes that begin with T, use the keypad to enter the letter T. To do this, press [1] twice. After each press of the key, the input mode field displays the selected letter. For example, if you press [1], S is displayed. If you quickly press [1] again, T is displayed. If you do not press the [1] key again, the letter T is selected. Once you have selected a letter, the cursor moves to the feature code beginning with that letter.

If there is no code beginning with that letter, the cursor moves to the next available letter. You can register up to ten Quick codes. To register Qcodes, press the Edit softkey. For more information, see Quick code measurement mode, page Press the Edit softkey to change the Qcode.

You can edit the entire code, or just the number at the end of the code. You can still use [DSP] to change the background displays. Entering values in feet and inches To enter values in feet and inches in an input screen, enter the elements, separated by periods.

If the denominator is 16, you do not have to enter it, and it is not displayed on the screen. For example, if you enter [2] [. If the denominator is 16, it is not shown on the screen. Jobs 3. C Caution — Before you use the instrument for the first time, check the job settings. Creating a new job Press [1] to open the Job Manager.

Press the Creat softkey to open the Create Job screen. Enter the job name. Press the Sett softkey to check the job settings. You cannot free space by deleting records in an existing job. Creating a control job A control job, or common file, stores coordinate data that is used by several field jobs. You can create a control job in the office. Press [1] or select Job to open the Job Manager. Move the cursor to the job that you want to use as the control job.

Press the Ctrl softkey. Press the Yes softkey. For more information, see Creating a control job, page When you enter a point name or number, the system searches in the current job first. If the point is not found in the current job, the search is automatically extended to the control job. If the point is found in the control job, the selected point is copied to the current job as a UP record. Jobs prefixed with? If a job is from an earlier version, you cannot open it, set it as the control job, or display its job information.

However, you can use the DEL softkey to delete it. Jobs created in version 1. Download all jobs before you update the software that is running on the instrument. Measuring Distances 3. For information on how to assemble the prism reflector, see Setting Up the Prism Reflector, page Sight the telescope to see crosshairs at the center of the prism reflector. Sighting a tiltable single prism Measuring distances While the instrument is taking a measurement, the prism constant is displayed in a small font.

Each time a measurement is taken, the distance is updated. If the average count is set to a value from 1 to 99, the averaged distance is displayed after the last shot. The field name SD changes to SDx to indicate the averaged data. For more information, see Status bar, page For more information, see [HOT] key, page These settings are job-specific.

If you need to change any of these settings, you must create a new job. For more information, see Job settings, page , and Settings, page Measurement settings The symbol then constantly runs from left to right over the prism constant in the display. The Target setting is used to apply better cyclic-error adjustment in distance measurement. It efficiently eliminates multipath reflection. The MSR only setting is the default measurement mode. The Confirm setting displays the Record PT screen before data is recorded.

The ALL setting is a quick shooting and recording mode. The instrument then returns to the BMS for the next measurement. Setting the horizontal angle to 0 Entering the horizontal angle Use the numeric keys to enter the horizontal angle. The displayed value is rounded to the minimum angle increment. Recording a foresight point after repeat angle measurement To activate repeat angle measurement, press [3] or select Rept. Sight the backsight and press [ENT]. Sight the foresight and press [ENT].

The horizontal angle is accumulated and the value is held again. To end repeat angle measurement, press [ESC]. When you have accumulated enough horizontal angle between the backsight and the foresight, press [MSR1] or [MSR2] to take a measurement to the foresight. The averaged horizontal angle is displayed.

This value is fixed until the process is finished or cancelled. Then press [ENT] to record. Horizontal angle hold To set the horizontal angle to the displayed value, press [ENT] or the Set softkey. Station Setup 4. To select a command from this menu, press the corresponding number key. The last function used is highlighted.

Press [1] or select Known in the Stn Setup menu. Enter a point name or number in the ST field. Enter the coordinates for the point. Press [ENT] after each field. The Backsight screen appears. Select an input method for defining the backsight point. To enter coordinates for the backsight point BS , press [1] or select Coord in the Backsight screen.

Enter the point name. If the point exists in the job, its coordinates are shown. If you intend to take a distance measurement to the BS, enter the height of target in the HT field.

Sight the BS on Face-1 F1. Press [ENT] to complete the setup. The QA screen shows the dHD and dVD values, which indicate the difference between the measured distance and the distance calculated from the known coordinates. To record the station, press [ENT]. To finish the station setup after taking a distance measurement, press [ENT]. ST and F1 records are stored to the current job.

To take an angle shot and proceed to the next measurement on Face-2, press the F2 softkey. To go directly to the Face-2 measurement after taking a distance measurement to the BS on Face-1, flip the telescope. Press [ENT] on Face The delta screen appears. To enter the azimuth angle to the backsight point, press [2] or select Angle in the Backsight screen. Having problems with your Digital Cameras? Looking for a owners manual for a Nikon total station dtm a Answers :.

Digital Cameras. Nikon,com and run your problem by them. Nikon D90 Digital Camera with mm lens. Nikon D40 I am only getting technical information in my LCD--I want to restore the camera to its original settings, but even though I have the digital Field Guide, and have looked at the owner's manual, have selected "Rest" in the menu, I can't seem to get back to having my LCD display the image at which I point he camera. Thanks for any information you may provide.

It will scroll through the index the one you are stuck on , highlight, histogram and then back to normal view. Nikon D40x Digital Camera. How to I get a copy of the Owner's Manual for the Vivitar v digital camera? I have spent well over an hour looking here and there and I thought this manual was supposed to be IN the package, not somewhere in outer space. Change To finish the setup and record the station, press in the BS field. You can use this menu at any time to change HT and T-P.

Enter the point name that you want to stake and press [ENT] You can also specify the point by code or radius from the instrument. Page 77 The default value is For more information, see Stakeout, page To go to the stakeout observation screen, press [ENT] If you have assigned a control job, and additional points are found in the control job, the softkey appears under the list. Page Program Key Enter the second point for the reference line. A list of matching points appears.

Page 82 [ENT] Enter the point name and feature code. You can also use this screen to change the HT value. Enter a negative value for a counterclockwise curve. When all factors have been entered, the instrument calculates the curve. To record the point, press on any observation [ENT] screen. The arc is stored in comment records. For more information, see RM records, page Measuring between the current point and the immediately preceding point To enter the RDM Continuous function, press or select in the Programs menu.

You can use an REM measurement to update the height of target. Take a measurement to the prism, sight the bottom of the prism pole, and press [ENT].

No distance measurement is required. Enter PT and CD. Page Recording Measurement Data You can also use the code list or the code stack. For more information, see Recording, page When the Ext. Comm field is set to SET If you use this method, the dimension of the angle offset is not stored as a CO record. Page Two-Prism Pole To record the point, press or the softkey.

The height of target is fixed to [ENT] 0. Sample records SS, 40, 0. Usually this is the taped distance from the instrument point.

Sample records SS,,0. The default elevation is given by P4. Enter a PT and CD value. The height of target HT defaults to the value used in the last measurement.

Page Measuring Circle Offsets If you have taken a distance measurement to the center of the circle, press the Calc softkey to calculate the offset using one edge angle observation. You can enter any value from — Page Introduction Press to move up or down the job list. Press to open the highlighted job.

Use this screen to specify whether to display values in Decimal-Ft or Ft-Inch. Page Deleting A Job A control job has the same format as a standard job. You can open and modify it like any other job, and you can use it to record any measured data. To set the control job: Highlight the job that you want to use. Page Displaying Job Information The Information screen shows the number of records in the job, the free space, and the date when the job was created.

Free space indicates how many points can be stored in the job. To return to the job list, press any key. Page Cogo. The softkey allows you to shoot the [ENT] point on the spot to use it in the calculation. The azimuth, horizontal distance, and vertical distance from the first point to the second point appear. Page [MSR2] to take a measurement.

After the measurement, a recording point screen appears. To use the point without recording it, press [ESC]. Data transfer to a personal computer or any data collectors is possible with the RSC interface, and also memory on board can store up to points, which will save you the purchase of data test1.

About this item. Time left. Seller Notes. Used and tested for power only.

   

 

Nikon total station manual download.Download Nikon Total Station DTM Instruction Manual | ManualsLib



   

Apr 26, Nikon DTN instruction-manual-english 1. Jan 14, Using the onboard software for a Nikon Total station. Using the onboard software for a Nikon Total station. Skip navigation Sign in. This video is unavailable. As a leading optical manufacturer As a leading optical manufacturer, Nikon is implementing superb optics into the DTM Each note can be up to 50 characters. The note is stored as a CO record in the raw data. To display a list of previously used notes, press the Stack softkey. The stack stores the last 20 notes.

Then press [ENT] to select the note. This function is available from any observation screen. Modify the default point name for the next record. Press [ENT] to confirm the new default point name. The new point name is appears as the default PT name on the input screen.

Bubble indicator To display the bubble indicator in an observation screen, press. When the leveling compensators are turned off, the text OFF appears on the screen. The DTM has vertical axis adjustment only. The current setting of leveling compensators is indicated by header characters :, , :, and after field labels such as HA, VA, SD, and HD in observation screens. For more information, see Header characters, page Whenever you press a [USR] key, the function that is assigned to that key is activated directly.

Hold down the [USR] key for one second to display the list of functions that can be assigned to the key. If you highlight a menu item and then press [ENT], a sub-menu appears. The first item on the sub-menu ends with the text [MENU]. If you select this item, the whole menu is assigned to the [USR] key. For more information, see [USR] key settings, page Use this screen to change the type of data that is assigned to [DAT].

Press [ESC] to return to the previous observation screen. For more information, see [DAT] key settings, page List Display 3. If the Page Up icon is displayed, there are more pages before the current page. If the Page Down icon is displayed, there are more pages after the current page.

To select an item from the list, move the cursor onto the item and press [ENT]. The default name for a new point is the last point name entered, with the last digit incremented. For example, if the last point name was A, the default name for the next point is A If the last character of the previous point name is alphabetic, the default point name is the last point name. When the cursor is in a PT point field, there are several ways to specify a point, or input coordinates.

Entering an existing point When you enter a known point name or number, the coordinates of that point are displayed briefly. A short beep sounds before the next screen appears or the next field is selected. The input coordinates are used in the calculation. They are not saved in the database. Recording an instant measurement You can also input a point by recording an instant measurement. To do this, press the MSR softkey. An observation screen appears. To change the height of the target, press the HT softkey.

To go to the point recording screen when you have finished the measurement, press [ENT]. Enter the point or code name. Press [ENT]. To display the stack, press the Stack softkey when the cursor is in the PT field. When you return to the point input screen, the selected point name is entered in the PT field, incremented by one.

For example, if you selected the A point, A appears in the PT field. The stack shows the last 20 point names used, in chronological order from last used to first used. Entering a point from the point list To display a list of existing points, press the List softkey when the cursor is in the PT field. When you return to the point input screen, the selected point name is entered in the PT field. You can add digits or alphabetic characters if required. Entering a code For more information, see [COD] key, page You can use numeric or alphanumeric names up to 16 characters long to identify codes.

Then use the keypad to enter the code. Entering a code from the stack The code stack is a list of recently used codes. The stack may contain up to 20 codes. To display the stack, press the Stack softkey when the cursor is in the CD field. The selected code is copied to the CD field. When the instrument is rebooted, the code stack is cleared. Entering a code from the code list To display a list of existing codes, press the List softkey when the cursor is in the CD field.

For more information, see Editing an item in the point list or code list, page If you highlight a layer in the list and then press [ENT], the codes and layers in that layer are displayed.

When you return to the input screen, the selected code is entered in the CD field. Items are shown in alphabetic order. You can also use the first character search to quickly find a code. For more information, see Advanced feature: Searching for a code by using the first character, page Advanced feature: Searching for a code by using the first character To find a code quickly when the code list is displayed, use the first-character search.

For example, to see feature codes that begin with T, use the keypad to enter the letter T. To do this, press [1] twice.

After each press of the key, the input mode field displays the selected letter. For example, if you press [1], S is displayed. If you quickly press [1] again, T is displayed. If you do not press the [1] key again, the letter T is selected. Once you have selected a letter, the cursor moves to the feature code beginning with that letter. If there is no code beginning with that letter, the cursor moves to the next available letter.

You can register up to ten Quick codes. To register Qcodes, press the Edit softkey. For more information, see Quick code measurement mode, page Press the Edit softkey to change the Qcode. You can edit the entire code, or just the number at the end of the code. You can still use [DSP] to change the background displays.

Entering values in feet and inches To enter values in feet and inches in an input screen, enter the elements, separated by periods. If the denominator is 16, you do not have to enter it, and it is not displayed on the screen. For example, if you enter [2] [. If the denominator is 16, it is not shown on the screen.

Jobs 3. C Caution — Before you use the instrument for the first time, check the job settings. Creating a new job Press [1] to open the Job Manager. Press the Creat softkey to open the Create Job screen. Enter the job name. Press the Sett softkey to check the job settings. You cannot free space by deleting records in an existing job. Creating a control job A control job, or common file, stores coordinate data that is used by several field jobs.

You can create a control job in the office. Press [1] or select Job to open the Job Manager. Move the cursor to the job that you want to use as the control job. Press the Ctrl softkey. Press the Yes softkey. For more information, see Creating a control job, page When you enter a point name or number, the system searches in the current job first.

If the point is not found in the current job, the search is automatically extended to the control job. If the point is found in the control job, the selected point is copied to the current job as a UP record. Jobs prefixed with? If a job is from an earlier version, you cannot open it, set it as the control job, or display its job information. However, you can use the DEL softkey to delete it.

Jobs created in version 1. Download all jobs before you update the software that is running on the instrument. Measuring Distances 3. For information on how to assemble the prism reflector, see Setting Up the Prism Reflector, page Sight the telescope to see crosshairs at the center of the prism reflector.

Sighting a tiltable single prism Measuring distances While the instrument is taking a measurement, the prism constant is displayed in a small font. Each time a measurement is taken, the distance is updated. If the average count is set to a value from 1 to 99, the averaged distance is displayed after the last shot. The field name SD changes to SDx to indicate the averaged data. For more information, see Status bar, page For more information, see [HOT] key, page These settings are job-specific.

If you need to change any of these settings, you must create a new job. For more information, see Job settings, page , and Settings, page Measurement settings The symbol then constantly runs from left to right over the prism constant in the display. The Target setting is used to apply better cyclic-error adjustment in distance measurement.

It efficiently eliminates multipath reflection. The MSR only setting is the default measurement mode. The Confirm setting displays the Record PT screen before data is recorded. The ALL setting is a quick shooting and recording mode. The instrument then returns to the BMS for the next measurement.

Setting the horizontal angle to 0 Entering the horizontal angle Use the numeric keys to enter the horizontal angle. The displayed value is rounded to the minimum angle increment. Recording a foresight point after repeat angle measurement To activate repeat angle measurement, press [3] or select Rept. Sight the backsight and press [ENT]. Sight the foresight and press [ENT].

The horizontal angle is accumulated and the value is held again. To end repeat angle measurement, press [ESC]. When you have accumulated enough horizontal angle between the backsight and the foresight, press [MSR1] or [MSR2] to take a measurement to the foresight. The averaged horizontal angle is displayed. This value is fixed until the process is finished or cancelled. Then press [ENT] to record. Horizontal angle hold To set the horizontal angle to the displayed value, press [ENT] or the Set softkey.

Station Setup 4. To select a command from this menu, press the corresponding number key. The last function used is highlighted. Press [1] or select Known in the Stn Setup menu. Enter a point name or number in the ST field.

Enter the coordinates for the point. Press [ENT] after each field. The Backsight screen appears. Select an input method for defining the backsight point. To enter coordinates for the backsight point BS , press [1] or select Coord in the Backsight screen.

Enter the point name. If the point exists in the job, its coordinates are shown. If you intend to take a distance measurement to the BS, enter the height of target in the HT field. Sight the BS on Face-1 F1. Press [ENT] to complete the setup.

The QA screen shows the dHD and dVD values, which indicate the difference between the measured distance and the distance calculated from the known coordinates. To record the station, press [ENT].

To finish the station setup after taking a distance measurement, press [ENT]. ST and F1 records are stored to the current job.

To take an angle shot and proceed to the next measurement on Face-2, press the F2 softkey. To go directly to the Face-2 measurement after taking a distance measurement to the BS on Face-1, flip the telescope. Press [ENT] on Face The delta screen appears. To enter the azimuth angle to the backsight point, press [2] or select Angle in the Backsight screen. In the AZ field, enter the azimuth angle to the BS point. ST and F1 records are stored in the job. See Advanced feature: Measuring F1 and F2, page Setting up a station using multiple point resection Measurements can be distance and angle, or angle only.

Calculation starts automatically when enough measurements are taken. You can delete poor observations and recalculate if necessary. You can also select the BS point. If the angle between known point 1 and known point 2 measured from the station point is extremely acute or extremely oblique, the resulting solution will be less reliable geometrically.

For geometric reliability, select known point locations or station point locations that are widely spaced. To start the resection, press [2] or select Resection in the Stn Setup menu. Enter the point name for the first observation point PT1. Enter the target height and press [ENT]. The F2 softkey is not available on the DTM To proceed to the next point, press [ENT]. Enter the second point PT2 and its height of target.

When the instrument has enough data, it calculates the station STN coordinates. For information about the View softkey, see Advanced feature: Viewing and deleting a measurement in resection, page When the results are satisfactory, record the station. Enter the height of instrument, if required. To change the station name, move to the ST field and edit or replace the text.

For more information, see Others settings, page BS defaults to the first observed point. To change the BS, press the Change softkey. The minimum data required for a resection is either three angle shots, or one angle shot and one distance shot. If you use a distance shot, the distance between the target points must be greater than the measured distance. Stn-Z is calculated from distance-measured data. If no distances are measured, then Stn-Z is calculated using angle-only measurements to points with 3D coordinates.

Advanced feature: Viewing and deleting a measurement in resection To check the measurements to each known point, press the View softkey on the calculated STN sigma or coordinate screen. Then press the DEL softkey. The STN coordinates are automatically recalculated. The input screen for the next PT appears. Setting up the station quickly without coordinates For the new point, MP 0, 0, 0 is stored as the coordinates.

When the ST is manually changed to a known point name, the station is set up on the coordinates of the known point. No default PT is assigned to the BS. Leave this field blank, or enter a BS point name. The backsight azimuth AZ defaults to zero, but you can change this. For more information, see Setting up a station with known coordinates or azimuth, page When the point is found, it is displayed briefly.

The cursor then moves to the HT field. The updated station coordinates are displayed. You can change the HI in this screen. When the HI is changed, the Z coordinate is updated before the station is recorded. You must complete a station setup before you use the Remote Benchmark function. This function always refers to the backsight point from the last ST record stored in the current open job. Enter station coordinates for observations without recording data 2.

To store raw data, use one of the other functions in the Stn Setup menu. This function does not store an ST record in the job. You can use this function without an open job.

The current instrument XYZ values are shown as the default. The display returns to the BMS. Enter a known point as P1. If you enter a new point name, a coordinate input screen appears.

Choose how you want to define a known line: — To define the line by entering P2 coordinates, press [1] or select By Coord. If you select By Angle, the azimuth input screen appears. Enter the angle value and press [ENT]. A measurement screen appears. To check your measurement, press the DSP softkey. If you defined the line by entering the P2 coordinates, the difference of HD dHD and VD dZ between your measurement data and input coordinate data are displayed.

Enter the station name, the height of instrument HI , and a feature code CD if required. Backsight BS defaults to the first point P1. To change it, highlight the BS field and then press the Change softkey. Specifying the stakeout point by angle and distance To display the input screen for the distance and angle to the target, press [1] or select HA-HD in the Stakeout menu.

Enter the values and press [ENT]. When the measurement is completed, the differences between the target position and the stakeout point are displayed. You can use this menu at any time to change HT and T-P. Every time you press [DSP], the next screen appears. To record the stakeout point, press [ENT]. Press [ENT] to record the point. After recording the point, it returns to the observation screen. You can continue observation, or press [ESC] to input another angle and distance for stakeout.

To start a stakeout by coordinates, press [2] or select XYZ in the Stakeout menu. Enter the point name that you want to stake and press [ENT]. You can also specify the point by code or radius from the instrument.

If several points are found, they are displayed in a list. Highlight a point in the list and press [ENT]. The delta angle and the distance to the target are shown. Ask the rodman to adjust the target position. When the target is on the intended position, the displayed errors become 0. For more information, see Using [DSP] to switch between display screens, page To record the point, press [ENT]. The default value is For more information, see Stakeout, page After recording the point, the display returns to the observation screen.

If you selected a point from the list, the display returns to the list, unless all points have been selected. Press [ESC] to return to the point input screen. Enter the start point Fr and the end point To. The range between Fr and To must be less than points. If existing points are found between Fr and To, a point list is displayed. To go to the stakeout observation screen, press [ENT]. If you have assigned a control job, and additional points are found in the control job, the Ctrl softkey is displayed under the list.

It then guides you to stake out the points, one by one. Set up the baseline. Enter the total stake number in the Span total field.

The observation screen for the first stake from the instrument appears. You can calculate and guide up to double the number of the stakes. Enter the first point P1 of the line. If you press [ENT] without entering a PT name, you can enter temporary coordinates which are not recorded in the job. Alternatively, press the MSR softkey to measure a point. Enter the second point P2 of the line. Enter offsets to the line. Press [ENT] in a blank field to enter the value 0.

When a distance measurement is taken, the difference from the design point is displayed. This function works as in the angle-distance stakeout. Measuring distance and offset values along a specified line Press [1] or select 2Pt RefLine in the Programs menu. Enter the first point for the reference line.

Alternatively to enter the point by measuring , press the MSR softkey. The Record PT screen appears. Enter the second point for the reference line. A list of matching points is displayed. Highlight a point in the list and then press [ENT]. Enter the point name and feature code. You can also use this screen to change the HT value. Press [2] or select Arc RefLine in the Programs menu.

Enter the start of the curve point P1 and the azimuth of its tangent line AZ1. To enter P1 by direct measurement, press the MSR softkey. Choose a method to define the arc. P2 can be any point on the tangent line that is to exit the curve. Enter a negative value for a counterclockwise curve. When all factors have been entered, the instrument calculates the curve. If the curve length Len is too large for a circle of the given radius, it is shortened.

To record the point, press [ENT] on any observation screen. The arc is stored in comment records. The distance from the station point to the first point is displayed. The distances between the first and second point are displayed.

To change display screens, press [DSP]. Default point numbers are displayed. You can change these point numbers. To record a note, press [ENT] in the To field. For more information, see RM records, page Measuring between the current point and the immediately preceding point 1. Follow the procedure as for a radial RDM measurement. For more information, see Measuring between the current and the first point measured, page The preceding two points are 2:Radial.

Calculations are made with reference to the first point. Enter the height of target. Loosen the vertical clamp, and turn the telescope to aim at an arbitrary point. The difference in elevation Vh is displayed. Take a measurement to the prism, sight the bottom of the prism pole, and press [ENT]. Measuring distance and offset values on the vertical plane Enter two points to define the plane. When you press the MSR softkey, a temporary observation screen appears.

Enter a value in the PT and CD fields. Enter the second point on the vertical plane. Once the plane is defined, the calculated Sta and dZ values are updated as you move the telescope.

No distance measurement is required. Enter PT and CD. Enter three points to define the slope plane. To enter the point by direct measurement, press the MSR softkey. If you press [ENT] in a blank field, an input screen for temporary coordinates appears. These coordinates will not be stored. For more information, see Measuring distance and offset values on the vertical plane, page Once the plane is defined, the calculated a and b values are updated as you move the telescope.

You can enter the PT name from the point list or the point stack. For more information, see Entering a point from the point list, page 45, and Entering a point from the stack, page You can also use the code list or the code stack. For more information, see Entering a code from the code list, page 46, and Entering a code from the stack, page To record the point, press [ENT] on the last field. When recording sideshots, stakeout records and control shots from the Rept function, you can choose to store raw data only, XYZ data only, or both.

For more information, see Recording, page In an angle-only record, SD is always recorded as 0. If the point name that you want to record already exists in the job, an error message is displayed.

Depending on the type of existing record, you can overwrite the old record with the new data. For more information, see Recording Data, page The format of the output data is defined by the setting of the Ext. For more information, see Communications, page When the Ext. To enter the taped offset function, press [1] or select Tape in the Offset menu. If you have not taken a distance measurement before entering this function, a temporary measurement screen appears.

Enter offset distances from the measured point. The calculated coordinates are shown. Enter a PT and CD value. Raw data is also recalculated, based on the taped offset value. Measuring angle offsets To enter the angle offset function, press [2] or select Angle in the Offset menu. To take the angle offset, rotate the alidade and telescope. The measured distance HD remains unchanged. The XYZ data is also recalculated, based on the new angle. Then press [ENT] to record the measured distance with the updated angle value.

If you use this method, the dimension of the angle offset is not stored as a CO record. To enter the two-prism pole function, press [3] or select 2Prism Pole in the Offset menu. Enter the distance between the second prism and the target point. Alternatively, if you do not need QA information, you can leave the distance between the first and the second prism blank. If you do enter a P1-P2 distance, the QA screen appears.

Compare the entered value and the measured distance to check the accuracy of the observation. Sample records SS,14,0. The display moves to the next screen. Sight the alternative place on the same vertical line as the desired target point. To calculate the coordinates and the raw data of the target point, press [ENT]. The height of target is fixed to 0.

Sample records SS, 40, 0. The last record records the angle measurement to the ALT vertically offset point from the actual target point. Turn the telescope in the direction of the point that you want to store.

Enter the HD. Usually this is the taped distance from the instrument point. The target point is calculated and recorded as an SS record. Sample records SS,,0. To enter the corner point function, press [6] or select Corner in the Offset menu. Take a distance measurement to the first prism or target on the wall. Sight a second point on the same wall with the first point measurement. Sight the first point on the second wall. If the two walls are at right angles, press the Calc softkey to calculate the corner point by three points.

If you take a measurement to a fourth point, the corner point can be calculated as the intersection of two walls P1-P2 and P3-P4. The default elevation is given by P4. The height of target HT defaults to the value used in the last measurement. To record the corner point, press [ENT]. Sample records SS, 58, 0. The next three or four comment records are measured points.

Measuring circle offsets To enter the circle center calculation function, press [7] or select Circle in the Offset menu. If you have not taken a measurement to the circle before entering this function, a temporary measurement screen appears. Sight one edge of the circle and press [ENT]. If you have taken a distance measurement to the center of the circle, press the Calc softkey to calculate the offset using one edge angle observation.

Sight the other edge of the circle and press [ENT]. The instrument calculates and records the center of the circle. It also calculates the coordinates of the center point and the radius of the circle. Sample records SS,71,1. The following one or two comment records are angle-measured points. To enter the function for extending the slope distance, press [8] or select Input dSD in the Offset menu. Enter the slope distance that you need to add or subtract. You can enter any value from — Sample records SS,83,1.

Job Manager 5. If there are jobs stored on the instrument, the job list appears, showing all the stored jobs. The newest job is displayed at the top of the list. If there are no jobs stored, the Create Job screen appears. See Creating a new job, page Opening an existing job Control job.

Some of the job settings are different from the current job. Job was created in an older DB. Older files cannot be opened in version 1. Press [ENT] to open the highlighted job. When you open a job, all job settings are automatically changed to match those used in the open job. Press the Creat softkey in the job list. Enter a job name of up to eight characters. Do one of the following: — To check the job settings, press the Sett softkey.

Job settings The following settings are set when a job is created, and cannot be changed. This ensures that the data in a job is correctly stored in the database, and that all necessary corrections are applied when you store each record. Scale Factor 0. Use this screen to specify whether to display values in Decimal-Ft or Ft- Inch. Alternatively, to move to the next field, press [ENT]. These settings are separate from other temporary settings. Deleting a job In the job list, highlight the job that you want to delete.

Press the DEL softkey. A confirmation screen appears. After you delete a job, the display returns to the job list. Setting the control job If the point is found in the control job, it is copied to the current job as a UP record. A control job has the same format as a standard job. You can open and modify it like any other job, and you can use it to record any measured data. To set the control job: 1. Highlight the job that you want to use. Do one of the following: — To set the selected job as the control job, press [ENT] or the Yes softkey.

If a control job is already assigned, the newly assigned control job replaces it as the control job. To clear the control job selected, highlight the current control job in the job list and press the Ctrl softkey. Then press [ENT] or the Yes softkey to confirm. The Information screen shows the number of records in the job, the free space, and the date when the job was created. Free space indicates how many points can be stored in the job.

To return to the job list, press any key. Cogo 5. You can access this menu at any time from any observation or PT input screen. Calculating angle and distance between two coordinates To calculate a PT-PT inverse: 1.

Enter the first point number or name. These coordinates are not stored to the database. If you want to store the point, specify a new point name. The MSR softkey allows you to shoot the point on the spot to use it in the calculation. The azimuth, horizontal distance, and vertical distance from the first point to the second point are displayed.

To calculate a 3Pt angle: 1. Press [2] or select 3Pt Angle in the Inverse menu. P1 is the base point. Two lines are to be defined by P2 and P3, both from P1. Enter the point name, or use the MSR softkey to take a measurement to the point. Enter the second point P2 to define the baseline P1-P2. The angle dHA is measured from the baseline. Enter the third point P3 to define the second line P1-P3.

When you press the MSR softkey, a temporary measuring screen appears. After the measurement, a recording point screen appears. To use the point without recording it, press [ESC]. When you have entered three points, the instrument calculates the angle and distances.

There are three functions in this menu for recording new coordinate points. Enter the base point P1. Type the point name and press [ENT]. Enter the azimuth, horizontal distance, and vertical distance. If you do not enter a value in the dVD field, the value 0. A recording point screen with the calculated coordinates appears. Press [ENT] to store the point.

Traverse function calculates a new point based on the two defined points and angle, horizontal and vertical distances from the line defined by those two points. To enter P1 and P2, enter point names or take measurements to targets.

Enter the plus-minus angle, horizontal distance, and vertical distance from the baseline defined by P1-P2. To record the new point and return to the point input screen, press [ENT]. P1 base PT defaults to the previously recorded PT. P2 defaults to the previous P1. This is a convenient way to enter Traverse points. Enter the coordinates using the numeric keys. The default PT is incremented to the next value.

Calculating area and perimeter In the upper right corner of the screen, a counter indicates how many points you have entered. For more information, see Advanced feature: Entering a range of points, page An XY coordinate input screen appears. Continue to enter points until you have defined all the points in the lot. Then, press [v] to calculate the area and perimeter. The first and last points that you enter are joined to close the area. You must enter the points in the order in which they define the lot.

You can enter up to 99 points. If you chose to store the area, enter a name to identify the area and then press [ENT]. Enter the start point name in the Fr field and the end point name in the To field. You can include letters and hyphens in the point names, but the last character must be numeric.

Press [ENT] in To field to start searching for matching points. The counter shows the number of matching points found. When the search is complete, you are returned to the Input PT screen. Press the Calc softkey to calculate the area and perimeter, or enter point names in the PT field.

Calculating coordinates from line and offset To do this, enter a value in the AZ or P2 field. P2 is a second point on the line. A negative value in the Sta field means the opposite direction along the defined bearing line. You can change the Z coordinate here. The coordinates are stored as a CC record. Calculating coordinates using intersection functions There are four functions in this menu for calculating coordinates. Calculating a bearing-bearing intersection A bearing-bearing intersection is the intersection point of two lines.

To calculate a bearing-bearing intersection, press [1] or select Brng-Brng in the Intersection menu. Enter the first point name and press [ENT]. Alternatively, to measure directly to the point, press the MSR softkey. Define the first line by azimuth.